SKM Decorative Indoor Units are perfectly convenient for apartments, offices, hospitals, hotels and sports hall. The sleek and compact design of each decorative indoor unit takes very little space in the room and do not obstruct the windows or any openings. The fan coil units are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at high efficiencies and low noise levels.
SKM decorative split system are available in different models covering one TR to three TR (1 – 3 TR / 3.5 kW to 10.6 kW) at nominal AHRI condition, which make them ideally suited for many Application areas. The Outdoor unit a small foot print for space saving and a pleasant exterior appearance for the Indoor units. SKM decorative split system designed accordance with G.C.C regulations and to conform specifically ESMA, MEW and G-Mark standards. SKM decorative split units are suitable to operate in a wide range of ambient temperature. (Minimum outdoor operating ambient in cooling mode is 63°F (17°C), maximum is 125.6°F (52°C). SKM decorative split units are internally wired and all that required to be done on site is refrigerant piping, power supply, suitable Indoor unit installation and field wiring, which reduces the installation work and consequently keeps to a minimum cost.
SKM DC Inverter Hi Wall split system is available in different models covering one and a half TR to three TR (1.5 – 3 TR / 5.12 kW to 10.24 kW), which makes them ideally suited for many application areas. The outdoor unit has a small foot print for space saving and a pleasant exterior appearance for the Indoor units. The series is designed in accordance with all G.C.C harsh conditions and to conform specifically to ESMA and G-Mark standards. SKM DC Inverter Hi Wall split units are suitable to operate in a wide range of ambient temperature. (Minimum ambient in Heating mode is 5°F (-15°C), and the maximum ambient in Cooling mode is 140°F (60°C) for 1.5TR-2.5TR and 125.6°F (52°C) for 3TR). SKM DC Inverter Hi Wall split units are internally wired and all that required to be done on site is refrigerant piping, power supply, suitable Indoor unit installation and field wiring, which reduces the installation work and consequently keeps to a minimum cost.
SKM decorative split system are available in different models covering one TR to three TR (1 – 3 TR / 3.5 kW to 10.6 kW) at nominal AHRI condition, which make them ideally suited for many Application areas. The Outdoor unit a small foot print for space saving and a pleasant exterior appearance for the Indoor units. SKM decorative split system designed accordance with G.C.C regulations and to conform specifically ESMA, EWA and G-Mark standards. SKM decorative split units are suitable to operate in a wide range of ambient temperature. (Minimum outdoor operating ambient in cooling mode is 63°F (17°C), maximum is 125.6°F (52°C). SKM decorative split units are internally wired and all that required to be done on site is refrigerant piping, power supply, suitable Indoor unit installation and field wiring, which reduces the installation work and consequently keeps to a minimum cost.
MSKMP-CWMSD0 Hi Wall split system is available in different models covering one TR to three TR (1 – 3 TR / 3.5 kW to 10.6 kW), which makes them ideally suited for many application areas. These units are suitable to operate in a wide range of ambient temperature. (Minimum ambient in Heating mode is 19.4°F (-7°C), and the maximum ambient in Cooling mode is 125.6°F (52°C). Units are internally wired and all that required to be done on site is refrigerant piping, power supply, suitable Indoor unit installation and field wiring, which reduces the installation work and consequently keeps to a minimum cost.
MSKMP-HMF1 Hi Wall split system is available in different models covering three quarters TR to three TR (0.75 – 3 TR / 2.56 kW to 10.24 kW), which make them ideally suited for many application areas. The outdoor unit has a small foot print for space saving and a pleasant exterior appearance for the Indoor units. The series is designed to conform SONCAP standards. Units are suitable to operate in a wide range of ambient temperature. (Minimum ambient in Heating mode is 19.4°F (-7°C), and the maximum ambient in Cooling mode is 109.4°F (43°C. Hi Wall split units are internally wired and all that required to be done on site is refrigerant piping, power supply, suitable Indoor unit installation and field wiring, which reduces the installation work and consequently keeps to a minimum cost.
MSKMP-HMI1 Hi Wall Inverter split system is available in different models covering one TR to two TR (1 – 2 TR / 3.41 kW to 6.82 kW), which make them ideally suited for many application areas. The outdoor unit has a small foot print for space saving and a pleasant exterior appearance for the Indoor units. The series is designed to conform SONCAP standards. Units are suitable to operate in a wide range of ambient temperature. (Minimum ambient in Heating mode is 5°F (-15°C), and the maximum ambient in Cooling mode is 109.4°F (43°C) for 1 TR and 122°F (50°C). Hi Wall split units are internally wired and all that required to be done on site is refrigerant piping, power supply, suitable Indoor unit installation and field wiring, which reduces the installation work and consequently keeps to a minimum cost.